Digi Portserver Ts 16 User Manual
- Digi Portserver Ts 8 16
- Digi Portserver Ts 16 Manual
- Digi Connectport Ts 16
- Digi 16 Port Terminal Server User Guide
Portserver II User Card. Portserver II Command Reference Manual. Portserver II Hardware Installation Guide. Cable Guide: Portserver TS, Digi One, and Connect products only. Diagnostics, Utilities and MIBs. Product support RSS feed for PortServer II-16 RJ45 Search our knowledge base for articles related to this product. Expert Support. User Manuals. Portserver Configuration Guide and Reference Manual. Cable Guide: Portserver TS, Digi One, and Connect products only. General Documentation. PORTSERVER 8/16 Datasheet. Diagnostics, Utilities and MIBs. Product support RSS feed for PortServer 8/16 (legacy) Search our knowledge base for articles related to this product. The Digi PortServer intelligent terminal server gives you the ability to connect up to 16 RS-232 asynchronous serial devices (such as terminals and printers) to an Ethernet network. Both Twisted Pair (10BaseT) and Thinnet (10base2) cabling standards are supported via the appropriate connectors on the side of the PortServer box. Digi PortServer TS 16 and Pdf User Manuals. View online or download Digi PortServer TS 16 and Configuration And Administration Manual. View and Download Digi PortServer TS 8 configuration and administration manual online. PortServer TS 8 Server pdf manual download. Also for: Portserver ts 16, Connectware portserver ts 8/16. TS 8/16 PortServer® TS ConnectPort® EtherLite® LTS 8/16/32 PortServer® TS MEI. PortServer TS 8/16 serial servers deliver intelligent, reliable. And cost-effective RS-232/422/485 serial-to-Ethernet connectivity. They support data center console port management applications, as.
What you will need
Power cord
(PortServer TS 16 families only) DB-9-RJ-45
adapter
Quick Start Guide
PortServer TS 1 MEI (shown)
PortServer TS Family Series
Software &
Documentation
Ethernet cable not included
PortServer TS 16 MEI (shown)
PortServer TS
PortServer TS MEI
PortServer TS P MEI
PortServer TS H MEI
Wall and brick power supply
(PortServer TS families 1/2/4/8 only)
PN:(1P) 90000687-88 B
1 | Set serial DIP switch (MEI versions only) according to your serial device | |||
requirements. Pinout information available on back of quick start. | ||||
Switch | EIA-422/485 | EIA-485 | 2 | Connect |
Settings | EIA-232 | Full-Duplex | Half-Duplex | |
serial | ||||
Up/On | device | |||
* | * | 4 | ||
Down/Off | ||||
1 2 3 4 |
INSTALL | *If switch 4 is up, termination resistor |
is connected. | |
1, 2, or 4 | |
If switch 4 is down, termination resistor | |
Port | |
is not connected. |
Note for PortServer TS P MEI series only -
In EIA-232 mode, If switch 3 is down,
9V power is provided on pin 9 (DTR).
*If switch 3 is up, power on pin 9 is disabled
12 3 4 and 5V power can be enabled on pin 1 (RI) through the software interface.
3 | Connect |
power | |
supply |
3 | Connect | |
Ethernet | ||
cable | ||
LEDs will flash | Power (green) | |
during startup | on; power supply | |
Status (yellow) | ||
blinking; seeking or waiting for an | ||
IP address - for status codes, see User's | ||
Guide | ||
3 | Connect power cord | |
and flip power switch on |
INSTALL | |
8 or 16 | 1 |
Port | Connect |
Ethernet |
LEDs will flash during startup cable
Download kioti lk3054 parts manual. Kioti Lk3054 Parts Manual PDF Online FreeKioti Lk3054 Parts Manual PDF Online Free bring the positive think in the future? Reading Kioti Lk3054 Parts Manual PDF Online Free can be disappeared the readers stress with the daily routine.It makes the readers become relax and fresh.How to get Kioti Lk3054 Parts Manual PDF Online Free? It makes the readers have good and much knowledge. Kioti Lk3054 Parts Manual PDF Online Free is full of good knowledge and reference.
Power - steady blinking; seeking or waiting for an IP address
Link - on; physical network detected 10/100 - off; 10Mbit Ethernet detected,
on; 100Mbit Ethernet detected ACT - on; bad initialization,
off; ready,
blinking; network activity COL - on; Ethernet collision detected
PortServer TS 8
2 | Connect serial |
devices | |
*If you need help | |
with cabling, | |
see other side |
1 | Connect | 2 | PortServer TS 16 MEI |
Connect serial devices |
The PortServer TS 8/16 MEI settings are configured through the software. Complete the Quick Start Guide and go to the User's Guide for the procedure to configure the MEI ports. The ports are set to EIA-232 by default. If your device is not EIA-232, configure the MEI settings immediately after completing the Quick Start. The default settings will not harm your device, however, we recommend configuring the MEI settings immediately as a precaution.
Insert CD
Software &
Documentation
!You must disable firewall/antivirus software before running wizard.
Congratulations!
Configuration is complete.
Sears International Online ShoppingIf you are planning to visit the United States, or have friends and family here, shop at Sears to get everything you want—including gifts for yourself or others. Once you place an order, you (or someone you know) can pick it up at a Sears store, have it shipped to over 100 countries—whatever is most convenient for you. You can pay for your order in a store or even use an international credit card. At Sears could not be easier. User manual for sears kenmore dryer model 110. Shopping online in the U.S.
Digi Portserver Ts 8 16
Go to the User's Guide on the CD for more information.
If you have a UNIX system and it does not use an auto-mounter, you will need to manually mount the CD. See the back of this guide for UNIX specific instructions.
Follow wizard | Be sure to check Digi Support for |
the latest firmware updates at: | |
http://support.digi.com |
© Digi International Inc., 2006.
Digi, Digi International, the Digi logo, and PortServer TS are trademarks or registered trademarks of Digi International, Inc. in the United States and other countries worldwide.
All other trademarks are the property of their respective owners.
Accessing the CD from a UNIX System
Insert CD in system CD drive
1
UNIX | Software & |
Documentation |
2
Determine your CD device
Common names for CD-ROM devices:
NAME | EXAMPLE |
/dev/cdrom | /dev/cdrom |
/dev/cdrom/cdromn | /dev/cdrom/cdrom1 |
/dev/cdn | /dev/cd0 |
/dev/dsk/cktmdn | /dev/c1t2d0 |
To list descriptions of devices: AIX: lscfg
HPUX: - Make sure you have administrator privileges and your PATH includes /usr/sbin
ioscan -funC disk
Solaris: Most Solaris systems use an auto-mounter. See the man page on vold: man vold
If your system auto mounts the CD, skip to step 5. Auto Mount programs may use the volume information to define a mount point. If the CD volume label is 'Digi' then the mount point may be /cdrom/digi
3
Identify the mount-directory.
Some common pre-existing mount points:
/mnt/cdrom /cdrom
Or create your own: mkdir /mnt/mycdrom
HPUX - Check to see if pfs is running ps -ef grep pfs
If not, start the daemons: pfs_mountd&; pfsd&
4
Mount the CD by entering one of the commands from the following table:
Operating | Command | |||
System | ||||
AIX | mount -r-v cdrfs device mount-directory | |||
*HPUX | do not use mount, it will not operate correctly | |||
pfs_mount device mount-directory | ||||
See man pages for pfs and pfs_mount for more | ||||
information. | ||||
Linux | mount device mount-directory | |||
SCO | mount -r-F cdfs device mount-directory | |||
UnixWare | ||||
SCO | mount -r-f ISO9660 device mount-directory | |||
OpenServer | ||||
Solaris | mount -F hsfs device mount-directory | |||
(Intel & | Most systems use an auto-mounter. See the man page | |||
SPARC) | on vold: man vold |
device is the path to the device file assigned to the cdrom drive, mount-directoryis the directory where the Digi CD is mounted
*HPUX When finished, leave the CD directory and pfs_umount cd
pfs_umount mount-directory
(If you inadvertenly use umount instead of pfs_umount, kill the pfs daemons to remove the CD-ROM.)
5
Navigate to mounted CD directory, enter: ./setup
If you see DISPLAY permission errors when running the CD, you may want to verify your DISPLAY variable is set. To set the DISPLAY variable:
DISPLAY=localhost:0.0; export DISPLAY
AND/OR xhost +localhost
Pinouts
Pin 1
PortServer TS 8/16
ONLY
RJ-45 | EIA-232 | EIA-422/485 | EIA-485 | Optional 8-pin |
Pin | Full-Duplex | Half-Duplex | EIA-422 (Alt-4 Wire) |
RI | TXD- | TXD- | |
DSR | RxD- | RxD- | RxD- (B) |
RTS | RTS+ | n/a | TxD+ (A) |
GND | GND | GND | CGND |
TxD | TxD+ | TxD+ | no connection |
RxD | RxD+ | RxD+ | RxD+ (A) |
SG | SG | SG | SGND |
CTS | CTS+ | n/a | no connection |
DTR | RTS- | n/a | TxD- (B) |
DCD | CTS- | n/a |
Need help with cabling? | Digi TS EIA-232 Cable Adapter Reference | |||
Part number | Adapter | Application | ||
76000697 | Digi TS DB-9F | Bay Accelar, Nortel and other DB-9 DTE devices | ||
Cabling your serial devices to a | Console Adapter (4-pack) | |||
76000698 | Digi TS DB-25M | Sun Sparc, Sun Ultra, terminals, printers and other | ||
Digi Product is now simpler than ever | ||||
Console Adapter (4-pack) | DTE devices with DB-25 Female ports | |||
with a Digi Cable Adapter. While many | ||||
76000699 | Digi TS DB-25F | Cisco, IBM and other DTE devices with | ||
custom cabling solutions can leave you | ||||
with a cable that is either too long or too | Console Adapter (4-pack) | DB-25 Male ports | ||
short for your application, the | 76000700 | Digi TS DB-25M | Modems and other DCE devices with | |
Digi Cable Adapters are used with | Modem Adapter (4-pack) | DB-25 Female Ports | ||
commercially available CAT 5 cable of | 76000701 | Digi TS DB-9M | Modems and other DCE devices with | |
any length. Simply plug standard CAT 5 | Modem Adapter (4-pack) | DB-9 Female Ports | ||
cable into your Digi Product, connect a | ||||
76000692 | Digi TS DB-25M | For use with Printers. This adapter differs | ||
Cable Adapter to the other end and plug | ||||
Printer Adapter (4-pack) | from a Console Adapter in that it utilizes the | |||
the adapter into your device. Whether | ||||
DTR signal (instead of RTS) for hardware flow control | ||||
you need a crossover or straight-through | ||||
connection, or require a DB-9 or | 76000631 | Digi TS to | For use with Cisco and Sun RJ-45 Console ports. | |
DB-25 connector, there is a | Sun Netra / Cisco Cable | Also available in 8-pack and 16-pack quantities. | ||
Digi Cable Adapter solution. | (single pack) | |||
For additional cabling information, see the | ||||
63000042-01 | RJ-45 to RJ-45 | Can be used as a networking cable or combined with | ||
Cabling guide under Documentation on | ||||
Straight Through | one of the adapters as a serial cable. | |||
your CD. If you prefer to order cables, | Ethernet Cable |
see our website at http://support.digi.com
and select Cabling. | All RJ-45 cables and connectors are 8-pin. When using these adapters with modems or other applications that require |
DCD on pin 1, you must turn on altpin. If altpin is turned off, the hardware signal on pin 1 becomes DSR instead of | |
DCD. This alternative can be used if DCD is not required, and DSR is needed instead. Configure the altpin through | |
the web interface or the command line. See the User's Guide, MEI chapter or the set flow command in the Command | |
Reference on the Digi CD under Documentation for more information about setting the altpin. |
Quick start guide, Portserver ts family series, Run wizard install
PortServer TS Family Series
Quick Start Guide
*If switch 4 is up, termination resistor
is connected.
If switch 4 is down, termination resistor
is not connected.
Set serial DIP switch (MEI versions only) according to your serial device
requirements. Pinout information available on back of quick start.
Congratulations!
Configuration is complete.
Go to the User's Guide
on the CD for more
information.
Connect
serial
device
Connect
Ethernet
cable
Connect
power
supply
Insert CD
Follow wizard
© Digi International Inc., 2006.
Digi, Digi International, the Digi logo, and PortServer TS are trademarks or registered trademarks
of Digi International, Inc. in the United States and other countries worldwide.
All other trademarks are the property of their respective owners.
Software &
Documentation
Software &
Documentation
PortServer TS 1 MEI (shown)
PortServer TS 16 MEI (shown)
Connect
Ethernet
Digi Portserver Ts 16 Manual
cable
Connect power cord
and flip power switch on
If you have a UNIX system and it
does not use an auto-mounter, you
will need to manually mount the CD.
See the back of this guide for UNIX
specific instructions.
Connect serial
devices
Connect
Ethernet
cable
Connect
power
supply
PortServer TS MEI
PortServer TS P MEI
PortServer TS H MEI
PortServer TS
What you will need
PortServer TS 8
PortServer TS 16 MEI
Ethernet cable not included
The PortServer TS 8/16 MEI settings are configured
through the software. Complete the Quick Start Guide
and go to the User's Guide for the procedure to
configure the MEI ports. The ports are set to EIA-232
by default. If your device is not EIA-232, configure the
MEI settings immediately after completing the Quick
Start. The default settings will not harm your device,
however, we recommend configuring the MEI
settings immediately as a precaution.
*If you need help
with cabling,
see other side
Connect serial devices
1
2
3
1
2
3
1
2
4
RUN
WIZARD
INSTALL
8 or 16
Port
INSTALL
1, 2, or 4
Port
3
Be sure to check Digi Support for
the latest firmware updates at:
http://support.digi.com
1 2 3 4
*
In EIA-232 mode, If switch 3 is down,
9V power is provided on pin 9 (DTR).
If switch 3 is up, power on pin 9 is disabled
and 5V power can be enabled on pin 1 (RI)
through the software interface.
Note for PortServer TS P MEI series only -
Power (green)
on; power supply
LEDs will flash
during startup
Power
- steady blinking; seeking or
waiting for an IP address
Link
- on; physical network detected
10/100
- off; 10Mbit Ethernet detected,
on; 100Mbit Ethernet detected
ACT
- on; bad initialization,
off; ready,
blinking; network activity
COL
- on; Ethernet collision detected
LEDs will flash during startup
Up/On
Down/Off
EIA-232
EIA-422/485
Digi Connectport Ts 16
Full-Duplex
EIA-485
Half-Duplex
Switch
Settings
*
1 2 3 4
*
Status (yellow)
blinking; seeking or waiting for an
IP address - for status codes, see User's
Guide
Digi 16 Port Terminal Server User Guide
You must disable
firewall/antivirus software
before running wizard.
!
Power cord
(PortServer TS 16
families only)
Wall and brick power supply
(PortServer TS families 1/2/4/8
only)
DB-9 -RJ-45
adapter
PN:(1P)
B
90000687-88