L&t Er300p Meter User Manual

Posted on
Back to Company

User manual Smart meter demonstration board with DLMS/COSEM using ST7570 S-FSK modem with STM32™ and SPEAr™ Introduction The purpose of this user manual is to help the user to set up, run and evaluate a complete solution that demonstrates a smart metering system based on. Hi, You cannot collect data without suitable MRI(Meter reading instrument) or respective company applications. But u can see total commulative consumption.

Electronic Trivector meter, ER300P - PRIDE is a multi-purpose unit which integrate several functions and replace various equipments for metering energy parameters. It is light, compact and highly reliable. L&T has indigenously designed and developed the same at its state-of-the-art manufacturing facility at.

Type: Sensor
Description: ER300P is an energy meter that measures active, reactive and apparent energies on 3 phase 4 wire systems in all four quadrants
Features: 8 energy accumulators - kWh, kVArh lag, kVArh lead & kVAh in import and export directions; Measures instantaneous parameters - phase wise voltages, phase wise currents, powers, frequency, rising demand, phase sequence, power factor and date & time; Data collection is possible through optically isolated serial interface, using a PC or MRI, or on Modbus on RS485; Supports 'time of day' or 'time of use' operation, which is programmable; Maximum demand registers with programmable Block/Sliding methods, integration periods and energy types; Load survey recorders with programmable integration period and parameter selection; Able to detect tampering/fraud; Internal Battery option available to view display, collect data and to perform a manual reset during power failure.

L&t Electronic Trivector Meter Er300p User Manual


(Specification Sheet)

Copyright © 2005-2019 Modbus Organization, Inc. PO Box 628 Hopkinton, MA 01748. All rights reserved.

By using Modbus.org, you accept the terms of our visitor agreement and privacy policy.

Electronic kWh Meter

  • Single and three phase versions available
  • Current reversal indication
  • LED indication proportional to kWh for on-spot calibration
  • Six digit counter
  • Dust proof body, rugged construction, elegant polycarbonate casing
  • Not affected by mounting position
  • Not affected by external magnetic field
  • Earth load tamper indication in single phase energymeter.
    Three phase energymeters work even on neutral removal
Electronic kWh Meter

Trivector Meter: Type – ER300P

Er300p
  • 0.2 / 0.5 / 1.0 class accuracy
  • Multi tariff capability with programmable TOD
  • Three programmable maximum demand (MD) registers
  • Tamper / failure detection and record capability
  • Communication interface via optical port conforming to
  • IEC 1107 protocol/RS 2321RS 485
  • Battery back-up for data collection
  • Available in projection ft flush mounting versions

Trivector Meter:
Type – ER300P

Energy Management System, Power Navigator Type ER300N

L&t Energy Meter Er300p User Manual

  • 0.5 / 1.0 class accuracy
  • User friendly software for PC operation
  • Communication interface via RS485 port and MODBUS protocol
  • Back lit LCD display
  • Front panel programming

Energy Management System,
Power Navigator Type ER300N

Olympus vn-8100pc user manual 3.5 jack. VN-8000PCManuals For Download:-Adobe Reader® - Most Olympus digital products are bundled with this program and it is typically installed automatically during software setup. If the manual is not displaying properly, please check that your version of Adobe Reader is up-to-date.Registering your new purchase will activate your warranty and make it easier for you to use our customer care services.This new multipurpose software package provides advanced RAW photofinishing functions. If this program is not available in your PC or MAC, you can download it for free from Adobe. Free Download.Protect your Olympus product with an affordable extended service plan.Learn great tips about your product.

Flush Mounted Three-Phase Energy Meter: Type – ACRUX

  • Flush mounting – 96mm X 96mm overall size (Cutout size-92mm X 92mm)
  • Compact and light M/s L & Tight
  • Class I accuracy as per IS 13779
  • LED indication proportional to kWh for on spot calibration
  • Meter records correct energy
    • (a) Irrespective of current direction
    • (b) Balance and unbalance condition with any phase sequence

Flush Mounted Three-Phase
Energy Meter: Type – ACRUX

Intelligent Panel Meter: Type – QUASAR

  • All instantaneous and cumulative values
  • Flush mounting – 96mm X 96mm overall size (cutout size-92mm X 92mm)
  • Class I accuracy
  • Separate display of fundamental and total harmonic values for currents and voltages of all phases
  • Front panel programing
  • Communication interface via RS 485 port ft MODBUS protocol

Intelligent Panel Meter:
Type -QUASAR

Demand Controller: Type – ER300D

User
  • 4 output outputs for early alarms and tripping of non-essential loads
  • MD control by monitoring rising demand
  • 0.5 / 1.0 class accuracy
  • User friendly software for PC operation
  • Communication interface via RS 485 port & MODBUS protocol
Demand Controller:
Type-ER300D